Hinged doors with a seal that stops smoke as well as fire – on fire compartment boundaries, escape routes and stairwells. Most fire victims are killed by smoke, so designs often require S (smoke control) and C (self-closing) in addition to the EI class.

Sa or S200 and the EI class are stated in the fire safety report or bill of quantities. Smoke-control doors must always close by themselves, so we supply them with a closer and, where needed, an electromagnetic holder that releases them on a fire alarm signal.
Declarations of performance, conformity and installation, a label with class and serial number, and installation and maintenance instructions – the documents requested at building inspection.
Sa means cold smoke leakage is limited; S200 means the door was also tested with smoke at 200 °C. The marking is added to the class, e.g. EI2 60-S200C5.
Usually yes – we supply doors with both an EI class and an S rating. The fire safety report states which combination is required.
Only with an electromagnetic holder linked to the fire alarm that releases them to close in a fire. Wedging them open or removing the closer is not allowed.

Single and double-leaf steel doors for stairwells, corridors, boiler rooms and technical rooms.

Entrance doors for flats and offices that protect against fire and burglary, with panels of your choice.

For hotel rooms and apartments, in wood finish or any colour – without an industrial look.

Steel doors with large glass areas for corridors and entrances where light and visibility matter.
Describe what you need or paste the items from your bill of quantities. We reply to emails within two hours on working days and send quotations the same day, or within 24 hours at the latest.