Fire collars and sealants

Where pipes, cables and ducts pass through a fire-rated wall or floor, the gap around them must be sealed so the fire cannot spread to the next room. That is what fire collars, wraps, boards and sealants are for – the system is chosen by the wall type and the services passing through.

  • EN 1366-3
  • EI
Fire collars and sealants

Where they are used

  • Plastic drainage and water pipes
  • Metal heating and cooling pipes
  • Cables, cable bundles and cable trays
  • Joints and gaps in fire-rated walls

Versions and hardware

  • Collars and wraps with intumescent infill for plastic pipes
  • Fire-stopping sealants – acrylic and intumescent mastics
  • Coated stone wool boards for larger penetrations
  • Tested to EN 1366-3 (penetrations) and EN 1366-4 (joints)
  • Class EI to EN 13501-2

How to choose

The solution depends on the wall or floor type, the pipe material and diameter or cable type – and must match the manufacturer's tested system. For a quotation we need a list of penetrations (type and diameter of services, quantity), wall or floor type and thickness and the required EI class; it is best to send a bill of quantities or photos of the penetrations.

Certification

Delivered with

Documents on the product's performance and class, and installation and maintenance instructions – the documents requested at building inspection.

Fire collars and sealants

Frequently asked questions

How does a fire collar work?

The collar has an intumescent infill that swells in a fire and squeezes the plastic pipe shut as it softens – so the opening in the wall stays closed.

Can a penetration be sealed with ordinary sealant or foam?

No – the seal must be tested for the specific wall type and services. Ordinary sealant or foam does not hold back fire, and such a penetration will not be accepted at building inspection.

Is a collar needed on both sides of the wall?

It depends on the tested system – in walls a collar is often needed on both sides, in floors only on the underside. Installation follows the manufacturer's instructions for the specific system.

Related products

Smoke vents

Smoke vents

Roof domes and vents that release smoke and heat in a fire – also for ventilation and roof access.

  • EN 12101-2
  • roof access
Details and quote
Intumescent fire grilles

Intumescent fire grilles

Ventilation grilles that let air through and close by themselves in a fire – for doors, walls and ceilings.

  • EI
  • doors · walls
Details and quote
Fire doors

Fire doors

Single and double-leaf steel doors for stairwells, corridors, boiler rooms and technical rooms.

  • EI2 30 · 60 · 120
  • any RAL
Details and quote
Smoke-control doors

Smoke-control doors

Hinged doors on fire compartment boundaries with a seal that also stops smoke.

  • Sa · S200
  • EI2 60 · EI2 120
Details and quote

All products →

Contact

Request a quote

Describe what you need or paste the items from your bill of quantities. We reply to emails within two hours on working days and send quotations the same day, or within 24 hours at the latest.

Zlatko Matanović at his desk
Behind every quotation is our team – since 2010.
Attach your bill of quantities, drawings or photos below – or e-mail them to info@rigor.hr.
Attachments
No files chosen
PDF, JPG, PNG, Excel, Word or DWG – up to 5 files, 10 MB in total.