Roof domes and vents that open automatically in a fire to release smoke and heat from stairwells, halls and shopping centres – keeping escape routes clear and making access easier for firefighters. The same vents serve for daily ventilation, and the hatch version also for roof access.

  • EN 12101-2
  • roof access
Smoke vents

Where they are used

  • Stairwells in residential and office buildings
  • Production and warehouse halls
  • Shopping centres and car parks
  • Roof access for maintenance

Versions and hardware

  • Smoke and heat exhaust ventilators to EN 12101-2
  • Electric (24 V) or pneumatic opening
  • Connection to the smoke control panel and fire alarm
  • Polycarbonate or acrylic dome, flat roof vent
  • Roof access version with handle and grab rail

How to choose

The number and size of smoke vents and the opening method are set by the fire safety design (aerodynamic free area). For a quotation we need the roof opening sizes, roof type, opening method and whether the vent should also serve for roof access or daily ventilation.

Certification

Delivered with

Documents on the product's performance and class, and installation and maintenance instructions – the documents requested at building inspection.

Smoke vents

Frequently asked questions

How does the dome open in a fire?

On a signal from a smoke detector or manual call point, the smoke control panel drives the motor or pneumatic cylinder and the dome opens. The panel has a backup power supply, so it works during a power cut.

Can the dome be used for ventilation?

Yes – with a ventilation switch the dome also opens in everyday use, while in a fire the smoke venting signal always takes priority.

What is the aerodynamic free area?

It is the effective area through which smoke escapes – smaller than the geometric opening because it depends on the dome shape and opening angle. The design specifies this value, and it is tested to EN 12101-2.

Related products

Intumescent fire grilles

Intumescent fire grilles

Ventilation grilles that let air through and close by themselves in a fire – for doors, walls and ceilings.

  • EI
  • doors · walls
Details and quote
Fire collars and sealants

Fire collars and sealants

Sealing pipe and cable penetrations through fire-rated walls and floors – collars, wraps and mastics.

  • EN 1366-3
  • EI
Details and quote
Fire doors

Fire doors

Single and double-leaf steel doors for stairwells, corridors, boiler rooms and technical rooms.

  • EI2 30 · 60 · 120
  • any RAL
Details and quote
Smoke-control doors

Smoke-control doors

Hinged doors on fire compartment boundaries with a seal that also stops smoke.

  • Sa · S200
  • EI2 60 · EI2 120
Details and quote

All products →

Contact

Request a quote

Describe what you need or paste the items from your bill of quantities. We reply to emails within two hours on working days and send quotations the same day, or within 24 hours at the latest.

Zlatko Matanović at his desk
Behind every quotation is our team – since 2010.
Attach your bill of quantities, drawings or photos below – or e-mail them to info@rigor.hr.
Attachments
No files chosen
PDF, JPG, PNG, Excel, Word or DWG – up to 5 files, 10 MB in total.