What the Croatian fire regulation requires for doors

In Croatia, the requirements for fire doors in buildings are set by the Regulation on fire resistance and other requirements buildings must meet in case of fire (Pravilnik o otpornosti na požar, NN 29/13, amended NN 87/15). Fire safety engineers derive the classes in the fire safety report from it, and we quote doors to that report. Here are the provisions that concern doors – summarised in plain language.

RIGOR · 10 November 2026 · 4 min read

Building subgroups

The regulation divides buildings by fire safety demand into subgroups ZPS 1 to ZPS 5 plus high-rise buildings – by number of storeys, height of the highest occupied floor, number of apartments or business units and number of users. The larger and more complex the building, the stricter the requirements. Buildings housing people who cannot evacuate on their own (hospitals, care homes, nurseries) are always at least ZPS 5.

Doors are “movable closing elements”

Openings are allowed in walls bounding fire or smoke compartments where they are needed for people to pass or for technical reasons. The regulation counts all door types – hinged, sliding, rolling, falling and lift shaft doors – as movable elements closing such openings, together with fire- and/or smoke-resistant dampers and curtains (Art. 16).

Door class relative to the wall

Doors may have a fire resistance equal to the wall they are fitted in or one grade lower, but not lower than E 30 – provided the doors take up no more than 20 % of the wall area (Art. 17(1)).

  • on fire compartment boundaries, elements EI 15, 20, 30, 45, 60, 90, 180, 240 are fitted
  • on smoke compartment boundaries, E-S elements with the same times
  • exceptionally, with proof by testing or calculation, EW 20, 30, 60 on a fire compartment boundary
  • in a fire wall (REI-M 90 of non-combustible materials) only doors with the same resistance as the wall may be fitted (Art. 17(6))

That is why the door class should always be taken from the fire safety report – it accounts for the wall, the size of the opening and the type of compartment.

Self-closing is mandatory

Movable elements closing openings must be fitted with a device for automatic closing (Art. 17(5)). For doors this means a closer – and if they have to stand open, a device that releases them in a fire, e.g. an electromagnetic holder linked to the fire alarm.

Stairwell doors

For protected stairwells, Table 3 (Annex 1) of the regulation also specifies the doors. Doors from apartments, business units and other rooms that open directly onto the stairwell (stairwell without a lobby) must be, depending on the building subgroup, from EI2 30 to EI2 30-C-Sm – doors that close by themselves (C) and limit smoke leakage (Sm), and in larger buildings combined with fire detection and smoke extraction or mechanical ventilation of the stairwell.

  • for corridors and rooms in basement storeys opening directly onto the stairwell: EI2 30 to EI2 30-C
  • for stairwells with a lobby: doors from the lobby to the corridor and stairwell E 60-C, doors from apartments and business units to the lobby EI2 60-C
  • the table does not apply to buildings with up to three apartments

Read more in the article Apartment entrance doors to the stairwell.

Door width on escape routes

The clear width of doors on an escape route must be at least 0.90 m, and at least 0.80 m in rooms where fewer than 50 people gather (Art. 35(3)). The clear width is the actual passage when the door is open – it is smaller than the door size, so check it before ordering.

Panic hardware and opening direction

Doors on escape routes – except in residential buildings and rooms where fewer than 50 people gather – must have panic handles, panic locks, push pads or push bars to EN 179 and/or EN 1125, and open in the direction of escape or slide, with systems for automatic or manual opening in a fire (Art. 40, as amended in 2015). More in the article Doors on escape routes.

Maintenance

The regulation states that fire safety elements must be maintained throughout the life of the building and that maintenance must not change the design solutions (Art. 1(6)). What to check is described in the article Fire door maintenance.

This article is a summary to help you find your way, not legal advice. The text of the regulation and the fire safety report for your building are authoritative.

Related products

Fire doors

Fire doors

Single and double-leaf steel doors for stairwells, corridors, boiler rooms and technical rooms.

  • EI2 30 · 60 · 120
  • any RAL
Details and quote
Smoke-control doors

Smoke-control doors

Hinged doors on fire compartment boundaries with a seal that also stops smoke.

  • Sa · S200
  • EI2 60 · EI2 120
Details and quote
Fire-rated entrance doors

Fire-rated entrance doors

Entrance doors for flats and offices that protect against fire and burglary, with panels of your choice.

  • EI2 30
  • burglar-resistant
Details and quote
Sliding fire doors

Sliding fire doors

For large openings in industry, warehouses and garages. They close automatically on a fire alarm signal.

  • EI2 120
  • electromagnet
Details and quote

All articles →

Contact

Request a quote

Describe what you need or paste the items from your bill of quantities. We reply to emails within two hours on working days and send quotations the same day, or within 24 hours at the latest.

Zlatko Matanović at his desk
Behind every quotation is our team – since 2010.
Attach your bill of quantities, drawings or photos below – or e-mail them to info@rigor.hr.
Attachments
No files chosen
PDF, JPG, PNG, Excel, Word or DWG – up to 5 files, 10 MB in total.